TROUBLESHOOTING THE HYPERCYL CYLINDER
Cylinder will not Extend SOLUTION Air is not turned on Open air valve Sideloading of rod Realign cylinder or tooling Cylinder is low on oil (low oil pin extended) Refill using HyperCyl HFP1 or HFP2 fill unit High Pressure rod is extended Retract HP (B2 port) Flow control is fully closed (where applicable) Open flow control to desired stroke speed
Cylinder will not Retract Extreme sideloading of rod Realign cylinder or tooling, loose mounting bolts High Pressure rod extended/ stuck Retract (B2) Contact Factory for more info.
Cylinder Slow to Extend/Retract Low air pressure setting Increase main FRL PSI AND VALVE STACK PSI Insufficient air supply Shop air must be 35-40 PSI minimum Undersized tubing Tubing should match size of NPT ports (ie. 3/8 NPT, 3/8 Tube) Flow Control problems (where applicable) Open flow control to desired stroke speed
Cylinder will not Sequence into High Pressure Incorrect air line installation Check cylinder manual for proper installation procedure Incomplete PLC programming Adjust as necessary Defective air valve Replace as necessary Defective pressure switch Replace as necessary
Cylinder Requires Frequent Refilling Worn/bad seals Return to factory for rebuild Insufficient timing of cylinder retract Refer to cylinder manual for proper timing
For all other questions or problems, please contact the Factory for more information. Phone: 734-529-8855 E-Mail This e-mail address is being protected from spambots. You need JavaScript enabled to view it
|